Overvoltage Protector for Current-Transformer Protection
CCTP-03
When a power system is in operation, it is imperative that the secondary of the current transformer(s) should not have an open circuit. When an open circuit occurs, an extremely high transient voltage will be induced, which can in turn damage the current transformers and the instruments at the secondary, or even posing a threat to personal safety. This CT secondary overvoltage protector offers protection from such accidental damage caused by secondary transient voltage.
Product Features
- Protection for three current transformers
- Operation panel with flat buttons for manually setting the desired triggering voltage and response time according to CT types or specific requirements
- Digital display showing current setting of triggering voltage and response time
- An LED light indicator for each of the three current transformers (the light turns on when an open circuit occurs at the secondary of its corresponding CT)
- Reset button for re-setting the triggering voltage and response time
- Power indicator
- Wide range of working source voltage (appropriate for use with a 110V or 220V working source)
Wiring Diagrams
Dimensions
Specifications
Max. num. of CTs at the same time | 3 |
Triggering voltage setting (range) | 0 ~ 150VAC |
Rated input current | 5A |
Response time setting (range) | 0 ~ 4 seconds |
Relay contact rating | 1C, 0 ~ 260V, 10A |
Operation environment | Ambient temperature: -20℃ ~ +70℃ |
Relative humidity: ≦ 96% RH | |
Altitude: ≦ 2500M | |
Working source | 85 ~ 265VAC |
Power consumption | ≦ 5VA |
Insulation | Power frequency withstand voltage: ≦ 2500V |
- Download Documents
CIC Company Profile
Learn about our company: history, strengths, products, global locations, and our Advanced Electricity Lab.
【Product Brochure】Overvoltage Protector for Current-Transformer Protection
Easy-to-print document, containing product description, features, specifications, and diagrams.
- Related Products
Outdoor-Type Current Transformers / Extended Range Current Transformers (ERCTs) for Revenue Metering (12~36 kV)
AWF-12, AWF-24, AWF-36
These outdoor current transformers for revenue metering, intended for 12~36 kV power systems, are used as part of an MOF (Metering Outfit) or for current monitoring. Insulated with UV-resistant cycloaliphatic epoxy resin, these medium-voltage (MV) current transformers are ideal for outdoor use and can be available as Extended Range Current Transformers (ERCTs) when requested.
24 kV Two-Core Current Transformer (“U-Shaped Top” Design)
EWF-20DI
2-core epoxy-cast current transformer for a 24 kV (max.) power system. For use with measuring or monitoring instruments, and protective relays. “U-shaped top” design for safety and for a shorter distance between two current transformers installed side-by-side, thus reducing the required width of the switchgear panel.
24 kV Epoxy-Cast Current Transformers for Indoor Application
EWF-20DA, EWF-20DB, EWF-20DD, EWF-20DE, EWF-20DS
For use in conjunction with energy meters or protective relays. Available in single-core, 2-core, and 3-core models. Insulated with Araldite® epoxy resin. Custom-made to meet various requirements.
Low-Voltage Current Transformer / Extended Range Current Transformer (ERCT) for Revenue Metering, Window-Type
ROS-A Series
Extended-Range Current Transformers (ERCT) for Revenue Metering offer precision in billing, with an operating range for accuracy up to 1% ~ 200% of rated current. Our window-type resin-cast current transformers “ROS-A Series” for low-voltage or LV (720 volts / 600 volts, or 0.72 kV / 0.6 kV) applications come in both ERCT and standard varieties. Range of specifications include Metering Class 0.15, Thermal Rating Factor up to 4.0, Current Ratios from 100:5A to 4000:5A, and multiple window diameter options. Special IP65 outdoor edition is available.
Zero-Phase Current Transformers (ZCT) for Ground-Fault Protection
EZ Series
Designed to protect the power system against leakage and earth faults, these zero-phase current transformers (ZCT) come in various window diameters. Epoxy-cast coil.
High-Voltage (HV) Outdoor Current Transformer, 52 kV & 72.5 kV
AWF-52, AWF-72
These high-voltage current transformers (52 kV or 72.5 kV), designed for outdoor use, are available in single-core and two-core varieties. Featuring extended creepage distance and insulated with UV-resistant cycloaliphatic epoxy resin, these current transformers can withstand solar ultraviolet radiation and IEC-defined pollution level III (“Heavy”). They’re especially ideal for regions with salt fog, high temperature, and high humidity.