Voltage Monitoring Sensor for Distribution Feeder Automation System (Indoor Type, for Underground Distribution Networks)
UV-5607
Voltage Monitoring Sensor “Type UV-5607” is designed for distribution feeder automation systems implemented for underground distribution networks.
This voltage monitoring sensor can be used in a 25.5 kV (max.) underground distribution network using distribution feeder automation system. This indoor-type voltage monitor, installed at underground cables in such a system, helps to provide voltage signals and data for monitoring and analysis purposes.
Voltage Monitoring Sensor Series for Distribution Feeder Automation System
Type |
UV 5607 (this product) |
|||
---|---|---|---|---|
Application |
Indoor |
Outdoor |
Outdoor |
|
Installation Location |
Underground System Cables |
SF6 Load Break Switch in Overhead Systems |
Pole-Mounted in Overhead Systems |
|
Rated Frequency (Hz) |
60 |
|||
Rated Voltage (kV) |
10 ~ 25.5 |
|||
Voltage Ratio (V) |
13200:5 |
13200:5 6600:2.5 |
6600:5 |
|
Accuracy |
± 1% (Phase Displacement: ± 1.5°) |
|||
Rated Power-Frequency Withstand Voltage (kV / 1 min.) |
50 |
60 |
28 (wet & dry) |
|
Rated Impulse Withstand Voltage (kV) (1.2 / 50 μs) |
125 |
125 |
110 |
|
Operating Temperature |
- 10℃ ~ + 65℃ |
N/A |
- 10℃ ~ + 65℃ |
|
Accessories (Optional) |
Cable * |
Yes |
N/A |
Yes |
Connector |
Yes |
N/A |
Yes |
|
Approx. Weight (kg) (without secondary lead wire) |
2.6 |
0.5 |
4.1 |
* Default cable specifications: AWG #21 outdoor cable (other specifications upon request).
Note: Further technical data, drawings, and dimensions available upon request.
- Download Documents
-
-
CIC Company Profile
Learn about our company: history, strengths, products, global locations, and our Advanced Electricity Lab.
-
- Related Products
-
-
Voltage Monitoring Sensor for Distribution Feeder Automation System (Outdoor Type, for use in SF6 Load Break Switch in Overhead Systems)
GDIO-C
Voltage Monitoring Sensor “Type GDIO-C” is designed for distribution feeder automation systems implemented for overhead distribution networks. This voltage monitoring sensor can be used in a 25.5 kV (max.) overhead distribution network using distribution feeder automation system. This outdoor-type voltage monitor, for installation in a SF6 load break switch in overhead systems, helps to provide voltage signals and data for monitoring and analysis purposes.
-
Voltage Monitoring Sensor for Distribution Feeder Automation System (Outdoor Type, Pole-Mounted in Overhead Systems)
EDIO-F
Voltage Monitoring Sensor “Type EDIO-F” is designed for distribution feeder automation systems implemented for overhead distribution networks. This voltage monitoring sensor can be used in a 25.5 kV (max.) overhead distribution network using distribution feeder automation system. This outdoor-type voltage monitor, to be pole-mounted in overhead systems, helps to provide voltage signals and data for monitoring and analysis purposes.
-