Standard Current Transformers
WHLB Series
WHLB Series Standard Current Transformers are mainly used as reference CTs for current transformer measurements and tests: error tests, characteristic tests, and so on.
About the Product
WHLB Series Standard Current Transformers are mainly used as reference CTs for current transformer measurements and tests: error tests, characteristic tests, and so on. These reference current transformers, available in various accuracy levels, are in compliance with IEC 60044 (IEC 61869) or ANSI/IEEE C57.13. They can also be made according to other requirements and specifications.
Specifications
Model | WHLB Series |
Primary Current Range | 5 ~ 5000 A |
Rated Secondary Current | 5A, 1A |
Accuracy Class | 0.05%, 0.02%, 0.01 % (or other values) |
Rated Secondary Burden | 0.2Ω (or according to user requirements) |
Power Factor | COSθ=0.8 (low voltage level) |
COSθ=1.0 (high voltage level) | |
Operation Range | 1% - 120% In |
Frequency | 50Hz, 60Hz |
Voltage Level | AC 600V (low voltage level) |
AC 10kV, 35kV, 50kV, or other values (high voltage level) | |
Note: Technical data listed above are default values. Customer specifications can be requested. |
- Download Documents
CIC Company Profile
Learn about our company: history, strengths, products, global locations, and our Advanced Electricity Lab.
【Product Brochure】Standard Current Transformers
Color brochure with technical specifications, and other information.
- Related Products
Digital Tester (Comparator) for Instrument Transformers
WHES-1Cx
Digital Tester (Comparator) for Instrument Transformers is designed for the testing of ratio error and phase displacement of current transformers and voltage transformers (potential transformers).
Standard Potential Transformers (Voltage Transformers)
WHJB Series
WHJB Series Standard Potential Transformers are mainly used as reference PTs (VTs) in a variety of potential (voltage) transformer tests: error tests, characteristic tests, and so on.
Burden for Current Transformer
WFY 47, 49 & 47-49
Burden for Current Transformer is mainly used for loading a CT during testing. Available in several structural designs for use in a variety of testing environments, this Burden for Current Transformer is compliant with IEC 60044-1 or ANSI/IEEE C57.13. Customer specifications can also be requested to satisfy different requirements.
Burden for Potential Transformer (Voltage Transformer)
WFY 95
Burden for Potential Transformer is mainly used as the secondary load of a PT (VT) during testing. Available in several structural designs for use in various testing environments, this Burden for Potential Transformer is compliant with IEC 60044-1 or ANSI/IEEE C57.13. Customer specifications can also be requested to satisfy different requirements.
Instrument Transformer Testing System
WHES Series
WHES Series Instrument Transformer Testing System is designed to measure various properties of electromagnetic current transformers and potential transformers (voltage transformers).